NOTICE OF SOFTWARE RELEASE: Revolution Software V3.57.0.0
01/28/26

•    1280 - New module 2.09 to support iQUBE3 
•    iQUBE3 - New module 1.00 for iQUBE3
•    Updates for 682 V1.15.00


NOTICE OF SOFTWARE RELEASE: Revolution Software V3.56.0.0
12/19/25

•    1280 - Add missing Adaptive filtering to Scale Wizard 
•    68x - Improve the Scale Wizard 
•    1280/68x/88x - Move the Batching Parameter from General to Setpoint section. 
•    General - Change how you close Connector Diagrams.
•    682 - Fix issue with checking Checkweigh IDs for sending configuration. 
•    682 - Create new modules for V1.14 support. 
•    General - Added a few more VKP 80III printer codes.
•    1280 V2.x+ - Tweak the Softkey Sample Display and change max length from 22 to 20. 


NOTICE OF SOFTWARE RELEASE: Revolution Software V3.55.0.0
11/12/25

•    48x - Removed note about Adaptive Filter Threshold 
•    48x - Added AUTO value to LCD Backlight Mode parameter
•    682 - Added new module to support 682 V1.13 Checkweigh feature
•    1280 - Fixed a couple issues with the Stream Editor Weight Token
•    1280 - Fixed typo in a softkey warning dialog box - Git #986
•    882IS - Fixed issue with 882IS IO Module connector image, added LPC version
•    88x - Fixed issue with deleting databases
•    1280/88x - Added 'Are You Sure' question to database delete button
•    1280/88x - Added preventing a space in database alias and field names


NOTICE OF SOFTWARE RELEASE: Revolution Software V3.54.0.0
10/08/25

•    1280 - New 2.08 module with support for enhanced fieldbus parameters
•    General - Fixed issue uploading data from indicator over TCP or RS232 with Echo Off 
•    1280 – Fixed unhandled exception when copying in the display editor with nothing selected


NOTICE OF SOFTWARE RELEASE: Revolution Software V3.53.0.0
8/29/25

•    680 - New module for V1.16 with support for 20 setpoints and custom units
•    682 - New module for V1.12 with support for 20 setpoints and enhanced serial scale capabilities
•    882D/1280 - Fixed issue with Analog Output config page and sending section configuration
•    1280 - Fixed issue uploading database data using TCP/IP
•    Added ® to Bluetooth in several places


NOTICE OF SOFTWARE RELEASE: Revolution Software V3.52.0.0
7/16/25

•    68x/LL3 - Suppress sending the ECHO parameter for ports configured as REMOTE in
•    882IS V2 - Changed CPU connector diagram
•    General - Enabled Cancel button when connecting with TCP/IP
•    882IS V2 - Added support for Peak Hold
•    882IO - Fixed incorrect reference to the config switch in the firmware updater
•    1280 - Increase the timeout value for Get Configuration from Device
•    1280 - Allow stream configuration while stream type is set to Off
•    682 - Fixed missing USB parameter during all parameter download
•    882IS V1 - Added the Peak Hold scale parameter for indicators FW V1.11+
•    882IS V1/V2 - Limited baud selections for IO Module Comm Ports to 57600 and 115200
•    882IS V1/V2 - Added ability to update firmware on the LPC IO Module


NOTICE OF SOFTWARE RELEASE: Revolution Software V3.51.0.0
3/27/25

•    CLS680 - Module is now fully functional 
•    880/882D - Better handle downloading blank database elements (handled like the 1280 now)
•    1280/880/882D - Change tool tip for the toolbar X while dealing with Databases
•    682 - Change the default for Aux Format 1 for version 1.12
•    682 - Change incorrect Ticket Editor tool bar icon for text entry
•    682 - Add new softkeys Print and Clear Accumulator


NOTICE OF SOFTWARE RELEASE: Revolution Software V3.50.0.0
2/21/25

•    682 - Added Load & Total (ag) print tokens and Shrink/Clear Shrink softkeys.
•    482AG - Create a new module for the 482AG.
•    1280 Removed Single Analog Input Option card and renamed DIO cards.
•    88x Updater - Change to close comm connection prior to opening the updater.
•    1280 - Disable scale wizard in menu if scale does not support it.
•    iQUBE2 - Change occurrences of iQube2 to iQUBE2.
•    Add next/previous arrows to the setpoint details tab for faster access to setpoints (current indicators only).
•    Change to make ASCII chart appear center parent form.
•    Change font used in ASCII chart.
•    Change DUMPALL timeout as it was too short for some USB adaptors.
•    Change so Revolution Main form will open center of the current screen (not last location).
•    CW90EU - Update version verification to work properly for version 1.0+.
•    882D - Remove incorrect Ethernet parameters from .rev file.
•    iQUBE2 - Fix the appearance of the help icon on the Format Editor screen.
•    1280 - Change appearance of some general scale parameters when a total scale is selected.
•    882D - Add Speed Sensor input connector diagram.
•    Ticket Editor - Code cleanup and bug fix for ASCII selections over 127.
•    882D - Fix issue with printing a configuration.
•    1280/68x - Rename IDC Print token to Company Name.
•    68x - Added SU token to the Ticket Editor toolbar.
•    882D - Select the correct initial format when entering the Ticket Editor.
•    882D - Fix incorrect Ticket Editor Toolbar button used for Text Entry.